secureRus.com
designing and developing security systems for You

 
|Home||
                 

Roger PR 302 Access control / Time & Attendance system

           
 

Roger PR402

Single Door Acess Controller

   
Roger PR302

Single Door Access Controller
with Built-in RFID/PIN Reader

Time & Attendance system

 
Access controller PR302
   
MAIN FEATURES
  • fully autonomic or networked operation,
  • Built-in keypad and proximity reader,
  • Card, PIN or [Card+PIN] identification,
  • Both side door control,
  • optional Wiegand or PRT(Roger) remote reader,
  • three NO/NC input lines,
  • one relay output and two transistors outputs,
  • support for door contact, exit button and alarm signalization,
  • XM-2 Remote I/O module support,
  • XM-8 Lift control module support,
  • RS485 communication interface,
  • 4 000 card users,
  • 250 access groups,
  • 99 time schedules, 128 periods per schedule,
  • holiday settings,
  • soft or hard local anti-passback,
  • non volatile 32.000 events register,
  • biometric reader support (High Security option),
  • T&A registration,
  • Toggle output for integration with Intruder Alarm System,
  • programming from PC*,
   
       
 
  • firmware upgrade through RS485,
  • UNIQUE (EM4001/2) cards,
  • Tamper contact,
  • Windows 95/98/NT/2K/Me/XP software,
  • CE mark.

    *- requires UT-2 communication interface
       
Technical specification
Operating voltage range     10 ..... 16 VDC
Current consumption     App 80 mA
Reading range     Up to 12 cm for ISO type cards (depend on card quality)
Cards     UNIQUE type, EM 400 1/2 compatible
Communication standard RS485     'Christmas tree' bus topology allowed, terminating resistors not required.
Cable distance between controller and terminal     150 m (500 feet)
Cable distance between controller and PC/ CPR panel     1,200 m (4000 feet)
Input lines     3 inputs, NO/NC types
Output lines     2 transistor output 1A rating and 1 relay NO/NC contacts output
Relative humidity     10 to 95 %
Operating temperature     0 to 55 degrees centigrade
Ingress protection     IP 30
Dimensions     105X105X31 mm
Weight     175 g
 
Ordering Information

PR302 - Controller with keypad. A self-adhesive cover is delivered with new controller so installer may if needed remove keypad and replace it with plastic cover.
PR302-BK - Controller without keypad.
UT-2 RS232/RS485 communication interface

     
           
     
               
      Software package to supervise Access control system


The RACS system Roger Access Control System is dedicated for small and middle-sized access control systems, it is capable of managing up to 10 sites (access networks) connected directly to PC or via TCP/IP.
Each access network may consist from up to 32 doors controlled on both sides and distributed over a 1200m distance

 

PR Master 4.0 is a program to supervise access control system based on control panels CPR-32 and CPR controllers delivered by Roger Company.
The application is adapted to work in operating systems: Microsoft Windows 98, Windows NT, Windows 2000 and Windows XP.
•The software package can also function in Windows 95, however update of this system is neccesary. Detailed update procedure description is on www.roger.pl site.
•The most stable work of RACS software can be achieved with systems Microsoft Windows XPand 2000.

Main features of PR Master 4.0:
•operate with access control system database,
•configurable database backup files,
•configuration export/import to/from external XML file,
•automatic or interactive system events reading,
•events registry review and reports generation,
•events export to text files and payroll software,
•user time and attendance in defined system areas,
•interactive commands to controllers,
•real-time online events display,
•events monitoring on local and remote computers,
•event notifications to email accounts,
•online events reports to TXT files,
•operator selectable filtering of events,
•event notifications to email accounts,
•visualization of system work on graphic background (object map).

Time & Attendance

Evaluating data for time and attendance purpose does not require installation of any additional devices (readers or controllers) or using other kinds of identification cards in the system.

To prepare the RACS system for T&A, it is necessary to mark controllers/terminals which will register employees' entrances or exits. Controllers can do both, access control and register events for T&A or can be assigned for one of mentioned function only. The RACS system offers several predefined types of passages (entrance, exit, business exit) and enables defining up to 150 additional types of passages as needed for the facility. For T&A purposes, we recommend using the PR302LCD controller, which enables dynamic modification of the type of the registered passage (with a keypad) or by the external push button or switch. In particular, it is needed where one controller registers multiple types of passages.

The system RACS alone does not perform the T&A function, nevertheless, it may deliver input data for specialized T&A (Time & Attendance or PAYROLL) software modules. The wide capabilities of defining the format of text files, to which the program may export events, allow the system to be supported by numerous T&A packages available in the market.

Click here for pdf version of the catalogue  
   
For information and sales please contact: Kenny 97523165 or email sales@securerus.com
 
     
secureRus reg no: 53041089M Tel no: 65 63451282 / Fax no: 65 62343769
111, North Bridge Road, #07-03, Peninsula Plaza, S179098
 
                       
|Top of page|