designing
and developing
security systems for You |
||||
|Home||
|
||||||||||||||||||||||||||||||||
Roger PR 302 Access control / Time & Attendance system |
||||||||||||||||||||||||||||||||
Roger PR402 |
Roger PR302
Single Door Access Controller |
|
||||||||||||||||||||||||||||||
MAIN
FEATURES
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||
Technical
specification |
||||||||||||||||||||||||||||||||
| Operating voltage range | 10 ..... 16 VDC | |||||||||||||||||||||||||||||||
| Current consumption | App 80 mA | |||||||||||||||||||||||||||||||
| Reading range | Up to 12 cm for ISO type cards (depend on card quality) | |||||||||||||||||||||||||||||||
| Cards | UNIQUE type, EM 400 1/2 compatible | |||||||||||||||||||||||||||||||
| Communication standard RS485 | 'Christmas tree' bus topology allowed, terminating resistors not required. | |||||||||||||||||||||||||||||||
| Cable distance between controller and terminal | 150 m (500 feet) | |||||||||||||||||||||||||||||||
| Cable distance between controller and PC/ CPR panel | 1,200 m (4000 feet) | |||||||||||||||||||||||||||||||
| Input lines | 3 inputs, NO/NC types | |||||||||||||||||||||||||||||||
| Output lines | 2 transistor output 1A rating and 1 relay NO/NC contacts output | |||||||||||||||||||||||||||||||
| Relative humidity | 10 to 95 % | |||||||||||||||||||||||||||||||
| Operating temperature | 0 to 55 degrees centigrade | |||||||||||||||||||||||||||||||
| Ingress protection | IP 30 | |||||||||||||||||||||||||||||||
| Dimensions | 105X105X31 mm | |||||||||||||||||||||||||||||||
| Weight | 175 g | |||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||
| Ordering Information
PR302 - Controller
with keypad. A self-adhesive cover is delivered with new controller so
installer may if needed remove keypad and replace it with plastic cover. |
||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||
| Software package
to supervise Access control system
|
||||||||||||||||||||||||||||||||
PR
Master 4.0 is a program to supervise access control system based on control
panels CPR-32 and CPR controllers delivered by Roger Company. Main features of PR Master 4.0: |
Time & Attendance Evaluating data for time and attendance purpose does not require installation of any additional devices (readers or controllers) or using other kinds of identification cards in the system. To prepare the RACS system for T&A, it is necessary to mark controllers/terminals which will register employees' entrances or exits. Controllers can do both, access control and register events for T&A or can be assigned for one of mentioned function only. The RACS system offers several predefined types of passages (entrance, exit, business exit) and enables defining up to 150 additional types of passages as needed for the facility. For T&A purposes, we recommend using the PR302LCD controller, which enables dynamic modification of the type of the registered passage (with a keypad) or by the external push button or switch. In particular, it is needed where one controller registers multiple types of passages. The system RACS alone does not perform the T&A function, nevertheless, it may deliver input data for specialized T&A (Time & Attendance or PAYROLL) software modules. The wide capabilities of defining the format of text files, to which the program may export events, allow the system to be supported by numerous T&A packages available in the market. |
|||||||||||||||||||||||||||||||
| Click here for pdf version of the catalogue | ||||||||||||||||||||||||||||||||
For
information and sales please contact: Kenny
97523165 or email sales@securerus.com |
||||||||||||||||||||||||||||||||
| secureRus
reg
no: 53041089M Tel no: 65 63451282 / Fax no: 65 62343769 111, North Bridge Road, #07-03, Peninsula Plaza, S179098 |
||||||||||||||||||||||||||||||||